with Purchase of Furnace & Air Conditioner
Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
When you have your furnace or plumbing systems repaired or installed by Hurlburt, you can be assured that it is done right. To read about other customer’s experiences with our furnace and plumber services in Elmwood, WI, check out our online reviews below!
Responded to service call for non-operational heat pump. Diagnosed issue as fan blade immobilization due to heavy snow accumulation, which triggered the scroll compressor safety control. Reset the safety control, verified proper system operation, and confirmed all wireless sensors are properly connected.
Responded to no-heat service call for Sanyo mini-split system. Upon arrival, observed blower operation without heat production. During troubleshooting and component inspection, system began producing heat while manipulating wiring connections, suggesting possible control board issue. System left operational but recommended control board replacement if intermittent heating problems recur.
Provided complimentary service appointment to review the previously installed water filtration system with customer who had received inadequate instruction during initial installation. Walked customer through proper filter change procedure and demonstrated maintenance requirements. Documented current system condition and provided customer with comprehensive operational instructions to ensure proper future maintenance.
Completed comprehensive annual plumbing inspection with no immediate issues identified. Documented existing water heater (Rheem) and shutoff valve installations. Customer expressed interest in potential future installations including water softener, tankless water heater, and re-piping for laundry and kitchen areas; service advisor scheduled to follow up next week regarding these upgrade options.
Serviced 2009 LP furnace with no heat complaint where blower motor was continuously running regardless of thermostat position. Diagnosed ignition failure code caused by tripped limit switch in inducer motor. Discovered severely rusted burners and secondary heat exchanger clogged with debris causing significant airflow restriction, which likely triggered the limit switch due to overheating. Reset system and restored temporary operation pending scheduled replacement of burners and cleaning of secondary heat exchanger.
Responded to service call for oil furnace that failed to re-light after running out of fuel. Diagnosed heavily sooted system due to lack of maintenance; performed complete tune-up including cleaning of nozzle, chimney, and all clean-out ports. Successfully removed accumulated soot, replaced nozzle, and verified proper system operation despite tank shutoff and filter remaining frozen outside.
Replaced faulty steam humidifier system with new unit as sold by Mike B. Installation included new humidistat, drain line, and patching of previous mounting holes in ductwork. System is now properly installed with digital controls and properly connected to existing HVAC infrastructure.
Performed scheduled maintenance flush on customer's two-year-old water heater with minimal sediment accumulation. Identified and repaired leaking copper pipe in the mechanical room during service. Completed full drain down and flush of water heater system, verified all repairs for leaks, and restored system to proper operation.
Performed scheduled furnace maintenance on 4-year-old FRP unit. Discovered and cleared completely plugged drain line that was severely restricting operation. Removed AC drain tube to clear significant blockage. Replaced plugged filter, cleaned system components, and set filter replacement reminder. Instructed homeowner on proper maintenance of humidifier drainage (currently draining into bucket) and recommended regular vinegar flush of drain line 1-2 times annually. Set humidifier pad reminder and accessed dealer system to update service records.
Responded to service call for sewer flies emerging from an open-site line connecting boiler to floor drain. Inspection revealed pipe was heavily contaminated with bacteria creating a breeding environment. Performed thorough line flushing using full pressure water and air snake to dislodge and remove accumulated biological matter. Attempted to use cable snake for additional cleaning but discovered equipment was non-functional.
Responded to warranty service call for previously installed drain assembly kit. Diagnosed issue where rubber o-ring had detached from sink drain. Replaced defective o-ring and verified proper drain function.
Responded to service call for oil furnace leaking around filter area. Diagnosed issue as insufficiently tightened bleed screw from previous service. Tightened bleed screw properly and cleaned up oil spillage from floor to resolve the leak.
Performed scheduled bi-annual maintenance service on all HVAC equipment. Installed new steam humidifier canister, replaced filters, and inspected boiler in main shop. Identified need for steam humidifier nozzle repair and prepared for installation of customer-supplied thermostats.
Responded to no heat call for 18-year-old furnace. Diagnosed intake vent obstruction due to frost and snow accumulation. Customer had already cleared blockage prior to arrival, which restored proper operation. Performed visual inspection confirming furnace functionality. Advised customer about keeping intake vent clear, particularly due to vulnerable location under deck, and recommended scheduling annual maintenance.
Responded to no-heat call where furnace was not turning on. Upon arrival, system was operational but diagnostic testing revealed a faulty pressure switch. After thorough evaluation, recommended replacement of both pressure switches to prevent future failures. Customer approved service, and replacement parts have been ordered.
Responded to warranty service call for boiler maintenance. Replaced oil nozzle on existing boiler system located in basement utility room. Performed operational testing after installation to verify proper functioning of the heating system. All systems working correctly upon completion.
Performed annual PM service on oil boiler system. Changed oil filter but deferred nozzle replacement due to non-standard size requirement on Weil McClain unit. System inspection showed proper boiler temperature/pressure readings and normal pump operation. Addressed customer concerns about discolored domestic water, explaining this was unrelated to boiler system and likely due to stagnant water in pipes. Will return to complete nozzle replacement with correct size.
Conducted comprehensive drain inspection and maintenance service throughout residence. All interior drains were successfully cleared through snake/augering process and verified to be operational. Identified main line as the source of primary blockage, which was left for Roto-Rooter service as pre-arranged with customer. Customer was informed that interior drain systems were functional but that main line requires additional service.
Replaced defective cartridge in stand-up shower to address handle leakage. Installed new shower valve to resolve valve leakage at shower assembly that had caused significant mineral buildup and water damage to surrounding tile. Additionally, installed new valve for laundry tub on lower level as requested.
Diagnosed no heat complaint on Ruud furnace less than 5 years old. Found limit switch tripped due to plugged air filter from ongoing basement construction. Cleared filter, reset furnace, and verified proper operation after extended run test. Quick inspection of heat exchanger confirmed no visible issues.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and Conditions | [cookie_preferences_link]
Web Design and Internet Marketing by RYNO Strategic Solutions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.