Performed routine follow-up inspection on 19-year-old furnace under rewards program. Conducted brief system check with no issues detected during this visit. Previously replaced ignitor during comprehensive winter service.
Performed annual service on customer's water treatment system, replacing the iron filter cartridge in the VIQUA filtration unit. Removed old iron filter media, properly disposed of waste material, and installed new filter. System functioning properly after service completion.
Performed routine furnace tune-up on 10-year-old residential system. Cleaned severely corroded flame sensor, inspected heat exchanger for integrity, flushed condensate trap, and replaced dirty air filter. All electrical components were checked and verified proper system operation with 55° temperature rise. System is functioning correctly with no issues identified.
Addressed warranty issue with exterior HRV ventilation system. Found mesh screen had fallen out due to vent hood becoming unclipped. Reinstalled screen, secured vent hood with screw, and applied caulk to prevent future detachment. Also inspected secondary hood as requested - all components now properly secured and functional.
Responded to water leakage issue near furnace caused by cracked condensate trap. Replaced trap, performed comprehensive furnace maintenance including component inspection, replacement of humidifier panel and furnace filter, cleaning of routine components, and unclogging of furnace drain. System now operating properly with no leaks observed.
Cleared a jammed garbage disposal, restoring functionality to a clogged sink. Noted significant issues requiring further attention including corroded dishwasher shutoff valve, leaking dishwasher door, and deteriorated laundry tub faucet. Recommended scheduling a service advisor consultation with client's son to discuss necessary plumbing repairs.
Responded to customer complaint of clean room not cooling properly with temperature rising to 74°F. Upon arrival, room temperature had already decreased to 69°F matching thermostat setpoint. Inspected both HVAC units serving the clean room and found them operating normally with clean outdoor coils. Pressure tested both systems and found similar readings, though cold outdoor conditions made precise diagnosis difficult. Unable to identify definitive issues with either unit. Advised customer that further diagnosis would require assessment during warmer weather conditions, but confirmed units are currently operational with no visible ice formation.
Responded to no-heat callback on Comfortmaker furnace (approximately 4 years old) that was experiencing ignition fault codes. Diagnosed a plugged condensate trap that was causing the pressure switch connected to the LP gas regulator to trip. Removed trap, performed thorough cleaning, reinstalled components, and verified proper operation with multiple test cycles.
Responded to no-heat call for a 30-year-old furnace with intermittent pilot light issues. Upon inspection, discovered multiple cracks in the heat exchanger and severely plugged burners creating hazardous ignition conditions. Due to safety concerns and the deteriorated state of critical components evidenced by extensive rust and oxidation, the unit was tagged out of service. Arranged for sales advisor to discuss replacement options with homeowner.
Performed site assessment for customer requesting estimate on ductwork replacement and return additions. Inspected existing HVAC system including furnace unit and current ductwork configuration in basement. Created follow-up for advisor to complete comprehensive estimate for the requested modifications.
Performed comprehensive maintenance on client's mini-split HVAC system consisting of three units. Diagnosed and resolved heating issue by correcting remote control settings (one set to heat, one to auto). Completed full system service including filter cleaning and inspection of outdoor condenser unit, where mouse nesting material was removed from the condenser fan grill. Interior components and coils were inspected with no further issues found. Provided operational instructions to homeowner on proper remote control usage to prevent future heating problems.
Performed comprehensive furnace maintenance on 14-year-old FRP system. Verified proper temperature rise, cleaned air filter and drain, and inspected routine components. Identified moisture leakage issues from collector box and inducer motor (currently inactive), and documented electrical readings of 8.0 amps with clamp meter. System is currently operating effectively with adequate heating performance.
Responded to unit heater service call to install new fan motor. Upon arrival, determined that the replacement motor had a larger diameter shaft than the original, making the existing fan blade incompatible. Documented the issue with photographs of both the fan assembly and motor components. Submitted parts order form for the correctly sized replacement motor.
Responded to no-heat call for dual LP furnace system. Diagnosed dirty flame sensor on upstairs unit which was cleaned and heat exchanger inspected. Found failing blower motor on basement unit that required manual intervention to restart. Provided customer with replacement options for the basement furnace blower motor.
Performed comprehensive tune-up on 4-year-old Lennox furnace. Inspected and verified all components functioning within specifications. System successfully cycled through first and second stage operation with no issues detected.
Responded to a service call for a non-functioning boiler serving in-floor heat in shop area. Diagnostic testing confirmed igniter functionality and proper gas pressure, but combustion failure persisted. Inspection revealed a dead bird obstructing the exhaust vent, preventing proper ventilation. Disassembled exhaust components, removed blockage, and reassembled system. Upon restart, boiler ignited and operated normally. System includes wall-mounted tankless unit with copper distribution piping and PEX manifold configuration for radiant floor heating.
Responded to no-heat service call for 10+ year old furnace that was cycling on but shutting down after approximately 30 seconds. Diagnostic inspection revealed faulty ignitor preventing proper combustion. Visual inspection of heat exchanger showed no visible cracks or concerning issues. Replaced ignitor with customer's approval, then performed system test cycle to verify proper operation. Unit now functioning correctly with normal heat production.
Diagnosed and serviced two non-functioning natural gas heaters in shop. One unit had a blown low voltage fuse on control board which was replaced and verified through complete heat cycle testing with no recurring issues. Second unit diagnosed with failed fan motor; replacement ordered per approved estimate.
Responded to service call for non-operational Munchkin boiler in warehouse. Upon inspection, discovered pinhole leak in heat exchanger rendering the unit non-serviceable. Client will contact for replacement estimates as this is a secondary heat source. Additionally, restored proper pressure to main building boiler by adding water.
Performed routine maintenance and tune-up on a 2-year-old Furnace/Heat Pump system. Inspected blower assembly and conducted electrical parameter testing with multimeter, recording readings of 0.3 and 47.0. System is currently operating properly with no issues or concerns identified.