Recent Jobs and Reviews in Woodville, WI
Job Locations and Reviews
Provided estimate for replacement of two 30-year-old toilets with ADA-compliant units and presented multiple options to customer. Successfully installed two new ADA toilets upon approval. Additionally diagnosed low water pressure issue at kitchen faucet and determined that the touchless faucet's solenoid valve had failed and requires replacement.
Responded to no heat call for commercial office with dual furnace system. Upon arrival, found two separate split systems: one ceiling-mounted unit serving office area controlled by hallway thermostat, and one upstairs unit serving break room controlled by break room thermostat.
Diagnosed break room thermostat displaying low battery warning, preventing upstairs furnace from initiating. Replaced thermostat batteries and verified successful furnace ignition and operation. Inspected air filter which showed moderate dust accumulation. Recommended filter replacement for both units.
Investigated ceiling-mounted furnace which was short-cycling and tripping on high limit safety. Found severely restricted air filter causing inadequate airflow and overheating condition. Accessed unit through drop ceiling using ladder due to challenging installation location with limited workspace. Identified extremely dirty filter as root cause of limit trips and inadequate heating. Advised customer to replace
Responded to service call for kitchen sink reinstallation following new countertop installation. Mounted kitchen sink faucet and reverse osmosis faucet to new sink basin. Installed two new basket strainers per customer request. Reconfigured PVC drain assembly to accommodate significantly deeper sink basin, ensuring proper drainage pitch. Corrected previous reverse osmosis discharge line that had been improperly threaded directly into sink drain. Completed all plumbing connections and verified proper operation of both faucets and drainage system.
Responded to service call for furnace leaking water on 6-year-old unit. Upon inspection, identified failed condensate collector box as source of water leak. Removed defective collector box and installed replacement unit. Verified proper drainage through condensate system, confirmed no additional leaks, and tested furnace operation to ensure proper functionality.
Completed routine plumbing inspection with no issues identified. All plumbing systems, fixtures, and components were examined and found to be functioning properly with no leaks, defects, or areas of concern noted at the time of service.
Installed shut-off valve on gas heater located in garage per request. Verified proper operation of all gas appliances after installation by confirming successful ignition and normal function. Job completed successfully with no issues.
Replaced high limit safety switch on Lennox furnace per approved estimate. Completed installation according to manufacturer specifications and performed operational testing to verify proper system function. All safety parameters now within normal operating range and furnace is working correctly.
Responded to emergency call regarding water leaking from kitchen sink into basement. Diagnosed issue as drain backup at standpipe under kitchen sink, causing significant flooding. Successfully cleared blockage using drain auger and modified installation by raising standpipe height to prevent future flooding incidents and provide early warning of potential backups.
Diagnosed no heat issue on 10+ year old Goodman furnace with repeated ignition failure and lockout. Inspection revealed heavily rusted burners causing inconsistent ignition and a leaking cold end header box at typical failure point. Replaced burners to restore heating function and recommended header box replacement, which customer elected to defer. Heat exchanger inspection showed no current integrity issues.
Successfully replaced a variable speed combustion inducer assembly on an IBC boiler system as part of a sold repair. Performed comprehensive maintenance including disassembly and cleaning of the heat exchanger during the customer's first annual boiler tuneup under their membership. System is now operating properly with restored heating functionality.
Responded to service call for IBC boiler experiencing intermittent operation and combustion blower issues. Diagnosed fan motor problem likely caused by dislodged motor cover that became wedged against the motor wheel, causing imbalance and irregular fan speed cycling. Performed temporary motor adjustment to restore operation, but recommended replacement of motor and complete system tuneup due to lack of maintenance over past three years.
Responded to no-heat call for 5-year-old natural gas furnace. Diagnosed main limit switch failure (reading 0 ohms) and inadequate airflow due to improperly sized ductwork. Temporarily installed 130-degree limit switch to restore heat operation, though manufacturer specification calls for 120-degree switch. Advised customer that ductwork reconfiguration may be necessary to prevent future limit trips and overheating issues.
Diagnosed no heat condition on 33-year-old Lennox pulse furnace. Found failed spark ignition system with no replacement parts available due to equipment age. Applied safety tag to system and recommended consultation with comfort advisor regarding replacement options.
Inspected reverse osmosis system that had a constant leak. Identified issue with RO discharge line which had film over it. Discussed with homeowner about relocating the discharge line, but homeowner opted not to invest in repairs due to planned countertop replacement scheduled for spring.
Diagnosed Carrier furnace failure due to seized blower motor preventing proper heat distribution. Performed system inspection finding severely clogged air filter and verifying functionality of flame sensor, ignitor, and burners. After cycling the furnace, confirmed blower wheel inoperability requiring blower motor replacement. Provided customer with replacement options.
Performed diagnostic inspection on 15-20 year old natural gas forced air furnace following customer's new enrollment in Family Rewards program. Identified and cleared plugged condensate drain that was causing intermittent operation issues as water would accumulate and trigger shutdown until drained. Conducted comprehensive maintenance including heat exchanger inspection and electrical component testing with multimeter verification. Replaced aging thermostat with difficult buttons. System now operating normally with proper drainage.
Repaired a leak in the domestic cold water system originating from a 90-degree fitting after the water meter. Removed the faulty fitting, then re-sweated a new 90-degree fitting to restore proper system operation.
Responded to emergency service call to address main water line leak in basement. Successfully replaced faulty valve before the water meter after city water shutdown. Additionally, removed old saddle valve under kitchen sink and installed new valve for refrigerator icemaker connection, restoring proper water supply to both systems.
Temporarily reinstalled customer's toilet with new wax seal and proper shimming following previous flooding incident and remediation work. Confirmed proper function of recently purchased toilet components. Customer advised this is an interim installation, with future service required for toilet removal during flooring replacement and final reinstallation once flooring work is complete.
Responded to no-heat call for 4-year-old furnace with reported flashing red light and ignition issues. Upon arrival, furnace was operating normally. Performed comprehensive diagnostic testing using Fluke 365 True RMS Clamp Meter on electrical components and inspected ignition system. Checked pressure switch, hot surface ignitor, and gas valve functionality. Examined blower motor assembly and verified proper gas line connections. Cleaned and replaced air filter to ensure optimal airflow. No immediate concerns identified; system functioning properly at completion of service.