We’ve assisted homeowners for over 65 years and will proudly service your home as well.
Whether you live north on Akron Ave or south by UMore Park, you know how fiercely cold the winter can be. We’ll help you stay warm through expert HVAC installations, maintenance, and repairs. That expertise extends to furnaces, boilers, heat pumps, and many other technologies.
Let Us Help You Stay Warm!
- Heating Repair: If you’ve experienced a heating malfunction, you want the system fixed the right way the first time around. That’s what our technicians deliver through expert workmanship and premium parts and materials.
- Heating Installation: Our technicians install all types of heating solutions, including more advanced solutions like radiant heating, solar-power-assisted heating, and dual-fuel heat pumps.
- Heating Maintenance: The Hurlburt Family Rewards Program provides the seasonal heating maintenance your system needs at a discount. Avoid unexpected heating failures this winter, and know your family is safe from toxic gases and other issues.
Seasonal changes have made expert home cooling services more a necessity than the luxury it once was. Our team helps customers choose practical solutions and maintain them for maximum energy efficiency.
Here Are Some of the Things We Can Do:
- Cooling Repair: Cooling systems often give you signs of a problem long before there’s an outright failure. These may include rising electricity usage, uneven cooling, short cycling, and musty odors.
- Cooling Installation: There is a wide range of ducted and ductless cooling technologies that we can customize for your home. Many customers enjoy home-wide central systems, while others prefer the inherently zoned approach of a mini-split.
- Cooling Maintenance: As a Hurlburt Family Rewards Program member, you’ll get a cooling tune-up each spring before the warm weather arrives. It will help you avoid unexpected repairs and dramatically lower your system’s energy consumption.
You need an expert who understands the local plumbing difficulties you face, and that’s what we deliver. Our team has extensive experience helping area homeowners overcome hard water and other water quality challenges. That includes implementing water purification systems that eliminate your reliance on bottled water.
All area homeowners should schedule routine electrical inspections. It’s an opportunity to catch deterioration early on and correct it before it becomes a hazard and an expensive repair. You can also explore the current electrical code and where you may want to upgrade.
Our Electrical Services Include:
- Electrical Repair: Electrical problems like flickering lights and warm outlets may indicate serious electrical hazards. Our team can also help you improve energy efficiency and diagnose why circuit breakers frequently trip.
- Electrical Installation: Upgrading your electrical panel can provide the amp coverage your home needs while letting you add lights, outlets, and other devices. Even if your home is newer, you may need surge protection that can protect your home against lightning and internal spikes.
The motto in Rosemount is the “Spirit of Pride and Progress.” One way we embrace it is by helping customers achieve more efficient home heating. That can be as simple as recommending a smart thermostat, which can lower heating costs by around 8%. Our team helps homeowners upgrade to condensing furnaces and boilers, which can reduce gas consumption by as much as 10%. We also help clients augment their heating systems with solar power and transition to hybrid configurations that feature heat pumps.
In addition, our team helps households protect against hard water. Most people in Rosemount get their water from the Jordan Aquifer, and the average hardness is 17 grains per gallon. A water softener can pay for itself by saving you hundreds annually. It can lower water heater operating costs. Water softening will also protect your pipes, fixtures, and other appliances.
We assist homeowners from Erickson Park to Spring Lake with all things electrical, too. Many customers are making their homes smarter with home automation features. Those with older homes should explore upgrading their electrical panels and replacing their wiring. Standby generators are a popular upgrade as well. Harsh winter weather can result in extended power outages, and a generator protects you by powering heating, lights, refrigerators, and freezers.
Hurlburt is a home services provider that has been in business for over 65 years. We embrace small-town culture but have the tools and experience to get the job done. Our company is a Lennox Centurion Award winner, but our team installs and services all brands and models.
We offer year-round availability and an around-the-clock live answering service. We also back all our work with a 12-month, 100% parts and workmanship warranty. That approach has earned us over 6,000 five-star reviews online and an A+ Better Business Bureau rating.
Do you need an electrician, a plumber, or an HVAC company in Rosemount? Call Hurlburt at your earliest convenience.
Hurlburt Heating & Plumbing has completed 20 jobs in Rosemount, MN between March 2026 and June 2026.
The most recent job was on June 12, 2026.
Responded to no cooling complaint on Bryant heat pump system. Upon diagnosis, identified failed capacitor and contactor preventing unit operation. Replaced both defective components and restored system to proper cooling function.
Responded to no cooling complaint on residential air conditioning system. Upon inspection, confirmed system was low on refrigerant with subcooling reading below 1°F. Found outdoor condenser coils heavily clogged with debris, causing elevated head pressure and masking true refrigerant charge level. System utilizes obsolete R22 refrigerant. Due to age of equipment (10+ years), refrigerant type, and condition of outdoor coil, recommended full system replacement. Scheduled replacement estimate for following day.
Responded to water leak originating from bathtub/shower area with visible water damage on ceiling below. Upon inspection, identified failed silicone seal around tub spout as source of leak. Removed deteriorated caulking and resealed tub spout with fresh plumber's silicone to restore watertight seal and prevent further water intrusion.
Responded to emergency service call for non-functional water softener prior to customer's scheduled vacation. Upon arrival, performed diagnostic evaluation and confirmed unit was not consuming salt and failing to soften water supply. Assessed system components and determined water softener had reached end of serviceable life and was beyond economical repair. Provided estimate for complete water softener replacement system to restore soft water functionality to the residence.
Responded to no cooling complaint on 10+ year old Carrier air conditioning system. Upon inspection, diagnosed failed capacitor preventing compressor operation. Replaced defective capacitor with appropriate replacement unit, restoring cooling function. System tested and verified operational upon completion.
Replaced existing exterior hose bib with freeze-proof model to prevent cold weather damage. Installed up to 15 feet of PEX tubing from interior shut-off valve to new exterior fixture, utilizing close-quarter pro press jaws for secure copper connections in medium-access crawl space. Removed corroded original hose bib showing significant exterior staining and weathering on foundation area. Completed all connections with proper shut-off valve installation, tested system for leaks, and verified full functionality of new freeze-proof hose bib.
Responded to warranty callback for air exchanger and humidifier issues following recent AC installation. Upon arrival, diagnosed air exchanger not operating due to disconnected low-voltage wiring between unit, AC system, and wall switch control on main floor. Located loose wires in attic mechanical space and identified proper terminal connections. Reconnected and secured all low-voltage control wiring to restore air exchanger functionality and integration with HVAC system. Inspected Aprilaire humidifier unit and confirmed operational status; however, discovered humidifier water feed tube had become disconnected during previous installation work. Reconnected water supply line to humidifier to restore full winter humidity control capability. Due to scheduling constraints and time limitations, completed initial diagnostics and temporary corrections within available 30-minute window. Documented all findings with photographs showing wiring terminal connections and humidifier installation. R
Responded to outdoor spigot leaking inside the home. Upon inspection, found that a hose had been left connected to the exterior spigot over winter, causing the pipe to freeze and split. The frozen expansion resulted in a ruptured supply line behind the wall, allowing water to leak into the interior of the home. Documented the damaged piping and provided quote for complete spigot and pipe replacement to resolve the issue.
Completed annual AC maintenance tune-up on 14-year-old system under family rewards agreement. Performed comprehensive inspection, verified system operation with multimeter readings showing 33.51°F supply temperature, confirmed thermostat functionality displaying 68° room temperature with proper communication, and recommended hard start kit installation and comfort advisor consultation for aging equipment optimization.
Responded to a leaking outside spigot that was actively dripping when turned on. Water supply to the spigot had been shut off via the dedicated interior shutoff valve prior to arrival. Removed the failed spigot assembly and installed a new replacement unit, restoring full functionality to the exterior water connection.
Responded to service call for weak toilet flush and plumbing leaks in basement utility area. Upon inspection, identified plugged fill valve causing inadequate flushing performance and discovered active leak at P-trap assembly beneath toilet draining into floor drain. Additional leak found at main shutoff valve supplying laundry area. Replaced defective toilet fill valve and deteriorated supply line to restore proper flush function. Installed new main shutoff valve to eliminate leak at laundry connection. Replaced flanged tailpiece on drain assembly to resolve P-trap leak. All connections tested and verified leak-free. System restored to full operational capacity with proper water flow and drainage confirmed.
Responded to service call for non-operational air exchanger following recent AC installation. Upon inspection, discovered air exchanger unit was functional but all control wiring had been disconnected from the control panel. Unable to determine original wiring configuration or connection points. Documented existing conditions with photos showing Aprilaire humidifier control and furnace installation. Recommended follow-up visit with senior technician for proper air exchanger control wiring diagnosis and restoration.
Completed preventative maintenance tune-up on 6-year-old single-zone Lennox air conditioning system with no reported issues. Found and replaced dirty air filter; advised customer to change filter monthly for optimal system performance and efficiency. All components inspected and operating within normal parameters.
Completed annual cooling maintenance on 5-year-old air conditioning system and air exchanger. Performed comprehensive AC tune-up including refrigerant level verification, pressure testing, and component inspection. Refrigerant charge confirmed adequate with slightly low subcool reading, though system pressures remain within acceptable parameters. All mechanical and electrical components operating properly to manufacturer specifications, with unit confirmed fully operational. Noted exterior main water line leak requiring attention, likely requiring connection tightening.
Performed startup and system check on newly installed air conditioning unit. Verified proper refrigerant release from service ports and confirmed all connections were secure. Inspected brass service valves, refrigerant lines, and system components. All equipment operational with no issues identified upon completion of startup procedure.
Responded to service call for beeping water treatment system with A3 alarm code indicating UV lamp replacement needed. Inspected complete water filtration system including mineral filter tank and water softener with dual black tanks. Diagnosed electronic controller alarm, replaced UV lamp assembly, and performed comprehensive filter inspection and replacement on all filtration units to ensure optimal system performance in single visit.
Responded to outdoor water spigot leak caused by stripped backflow preventer and cross-threaded connections. Removed deteriorated fixture showing significant corrosion, worn brass threading, and mineral buildup from prolonged outdoor exposure. Installed new Woodford frost-free hose bib with proper threading and connections to eliminate leak and restore functionality to exterior water access point.
Responded to emergency water leak in basement caused by burst copper supply line to exterior hose bib. Upon arrival, confirmed water source had been shut off by homeowner following overnight flooding incident. Inspection revealed the hose bib was leaking through the ceiling when operated, with the connected copper pipe having ruptured at the connection point. Removed failed hose bib assembly and damaged section of copper supply piping. Installed new hose bib with replacement copper piping, ensuring proper connections and secure mounting through wall penetration. Tested system for leaks and verified proper operation before restoring water supply.
# Water Heater Tune-Up and Inspection Performed comprehensive tune-up and inspection on existing tanked water heater for homeowner preparing property for sale. Upon arrival, conducted thorough visual assessment of unit to determine age and operational condition. Inspected all major components including tank exterior, pressure relief valve, drain valve, gas connections, venting system, and burner assembly. Checked for signs of corrosion, leaks, or structural compromise on tank body and surrounding plumbing connections. Tested temperature and pressure relief valve for proper operation and verified discharge pipe configuration meets safety standards. Examined anode rod condition (where accessible) and assessed sediment buildup potential. Inspected gas line connections for leaks using approved detection methods and verified proper combustion air supply. Evaluated flue pipe integrity and secure attachment to ensure safe exhaust ventilation. Flushed sediment from tank bottom to improve he
Performed comprehensive maintenance on 16-year-old HVAC system including furnace and AC tune-up per non-member service request. Tested capacitor with multimeter showing reading of 63, and inspected metal components for wear. System is operational but showing age-related deterioration; customer has been informed of worn parts and replacement options have been provided via email.