To get assistance with your HVAC and plumbing repairs, maintenance, and installations, look no further! To see what our satisfied customers think about our HVAC and plumber services in Plum City, WI, read our reviews below.
Hurlburt Heating & Plumbing has completed 20 jobs in Plum City, WI between May 2026 and July 2026.
The most recent job was on July 8, 2026.
Hurlburt Heating & Plumbing has completed 105 jobs in Plum City, WI in the last 12 months. The first job there was in October 2015.
Performed preventative maintenance tune-up on residential air conditioning system. Upon arrival, found outdoor condenser unit heavily obstructed with dirt, dust, and debris accumulation throughout the coil fins and grille, significantly restricting airflow. Conducted thorough coil cleaning and system wash-down to restore proper ventilation. Initial testing showed 16° temperature drop across the evaporator coil. Post-cleaning diagnostics revealed borderline low refrigerant charge with superheat readings measuring 14-15°, indicating system is not operating at optimal efficiency. Advised customer of potential refrigerant deficiency and recommended monitoring system performance to determine if refrigerant charge adjustment will be necessary for peak operation.
Completed comprehensive air conditioning tune-up on a one-year-old system with no reported concerns. Performed full system inspection including filter, blower assembly, and evaporator coil—all components found clean with proper drainage confirmed. Conducted outdoor unit inspection with all routine components measuring within manufacturer specifications. Trimmed overgrown bushes encroaching on outdoor unit to restore proper airflow clearance and performed condenser cleaning. System operational testing conducted with fifteen-minute runtime confirmed proper performance with 20-22 degree temperature split across the evaporator coil. Recommended maintaining vegetation clearance at current trimmed distance to ensure adequate airflow and system efficiency.
Completed installation of new ADA-compliant elongated toilet per estimate specifications. Replaced existing toilet flange to ensure proper seal and stability. All internal tank components, including fill valve and flush valve assembly, were installed and tested for proper operation. Work included removal of old fixture, preparation of mounting surface, and secure installation of new two-piece toilet unit with all necessary hardware and wax ring seal. System was tested and verified to be functioning correctly with no leaks detected at supply line or base connections.
Performed scheduled maintenance on a 13-year-old single-head ductless mini-split system. Accessed and inspected internal components, finding the blower wheel heavily soiled with accumulated debris. Thoroughly cleaned the blower wheel and evaporator coils to restore proper airflow and system efficiency. Verified system operation with temperature split exceeding 20 degrees, confirming optimal cooling performance post-service.
Responded to no cooling complaint on residential air conditioning system. Diagnosed failed capacitor on condenser unit, replaced defective component, and verified proper system operation. Unit is operating efficiently and maintaining desired temperature setpoint.
Performed comprehensive air conditioning tune-up on one-year-old system as part of annual maintenance agreement. Cleaned outdoor condenser coils, inspected and tested capacitor and contactor for proper operation, and verified system performance with temperature differential measurement of 18 degrees across the evaporator coil. All components found operating within normal parameters with no issues identified.
Responded to a no-flush toilet complaint and discovered the main drainage line in the basement was severely obstructed with approximately five gallons of accumulated toilet paper. Upon inspection, identified a deteriorated section of cast-iron pipe with previous repair couplings that was causing recurring blockages due to rough interior surfaces and structural degradation. Disassembled the existing repair couplings, successfully cleared the obstruction, and restored proper drainage flow. Advised that the compromised cast-iron section requires replacement to prevent future blockages, as the degraded pipe condition continues to catch debris and will result in ongoing maintenance issues until permanently addressed with new piping.
Responded to emergency plumbing call for multiple leaks that developed overnight. Located and repaired broken copper water line behind toilet within wall cavity, requiring access through wall opening. Replaced deteriorated bathroom faucet and complete kitchen sink assembly due to age and failure. Performed minor repairs to toilet fixtures including supply connections and internal components. Addressed underlying pipe issues beneath kitchen sink area where corrosion and aging copper lines showed significant oxidation and patina buildup. All work completed according to provided estimate, with multiple fixtures requiring replacement due to extensive deterioration throughout the plumbing system.
Completed comprehensive AC tune-up and maintenance service under rewards program agreement. Verified system performance with 19-degree temperature differential across evaporator coil, inspected and confirmed air filter in good condition, performed condenser coil cleaning, and tested all operational functions of both indoor air handler and outdoor condensing unit. All equipment operating within normal parameters with no issues identified.
Completed replacement of 50-gallon electric water heater in basement utility area. Drained and removed existing unit, then installed new water heater of equivalent capacity using basic installation materials including copper piping, brass fittings, and flexible connectors. All electrical connections were properly secured, and unit was positioned against interior wall with appropriate clearances. Permit obtained as required by local code.
Responded to no hot water complaint and found 50-gallon electric water heater with burned-out heating elements and extensive age-related deterioration, including severely corroded piping connections. Inspected electrical panel and water heater condition, documented deteriorated components with photos. Recommended full unit replacement due to age and condition, provided estimate for new 50-gallon electric water heater installation with option for 40-gallon unit per customer preference, scheduled installation for following morning.
Completed comprehensive AC Rewards tune-up on two-year-old system. Found heavily clogged MERV 11 air filter restricting airflow; removed and installed temporary 1-inch filter to restore proper system operation. Removed outdoor unit covers and performed thorough washing to eliminate accumulated dirt and debris. Verified system performance with 22° temperature drop across coil and confirmed all components operating within normal parameters.
Completed annual air conditioning tune-up as part of membership agreement. Performed comprehensive system inspection including washing the condenser coil, checking all components, and verifying proper operation. System demonstrated excellent performance with a 23-degree temperature drop across the evaporator coil. Noted air filter approaching end of service life; homeowner will replace. All equipment operating within normal parameters.
Responded to no cooling complaint on residential air conditioning system. Upon arrival, found outdoor condensing unit not operating while indoor blower was running normally. Homeowner reported hearing a clunk noise prior to system failure and thermostat clicking but no cooling. Performed diagnostic testing on outdoor unit components. Capacitor tested within specifications. Voltage testing revealed contactor was not receiving 240V power supply, indicating failed contactor preventing compressor and condenser fan operation. Replaced defective contactor with new unit. Performed maintenance cleaning by rinsing condenser coils to remove debris and improve heat transfer efficiency. Started system and verified proper operation of all components. Outdoor unit engaged successfully, compressor running smoothly, and system restored to full cooling capacity. Unit operational and cooling home effectively upon departure.
Responded to service call for thermostat displaying temperature readings approximately 10 degrees off from actual room temperature on a 1-year-old cooling system and 3-year-old heating system. Diagnosed faulty thermostat as root cause of inaccurate temperature readings. Removed existing thermostat and installed new Honeywell thermostat, completed wiring connections, and performed full system setup and configuration. Verified proper operation of heating and cooling cycles, confirmed accurate temperature sensing, and tested system shutdown functionality to ensure thermostat cycled equipment correctly at setpoint.
Responded to no cooling call on 15+ year old Tempstar SmartComfort 2000 R22 system. Found mice had infiltrated outdoor unit causing contactor to fail - debris prevented contacts from closing properly. Cleaned contactor assembly and removed all rodent material from unit. Checked system operation and measured refrigerant pressures - unit slightly low on R22 but achieving 20-degree temperature split across evaporator coil. Noted condenser coil significantly plugged on back side, restricting airflow. Customer elected to defer coil cleaning and operate unit as-is to extend remaining service life. System restored to operational status but advised of potential freeze-up risk due to low refrigerant charge. Prepared estimate for contactor replacement as preventive measure given age of component and recent contamination. Unit functional at time of departure.
Completed comprehensive air conditioning tune-up and maintenance service as part of recurring preventive maintenance agreement. Performed full system inspection and diagnostics, identifying capacitor reading outside acceptable specifications. Replaced defective capacitor with proper replacement unit, performed complete condenser coil cleaning and wash-down, and verified system performance with temperature differential measurements confirming proper cooling operation.
Responded to a water leak originating from a reverse osmosis system that was previously installed. Upon inspection, identified that the adapter fitting connecting the supply line to the faucet had worked loose, causing a visible drip beneath the unit. Disassembled the adapter connection and thoroughly inspected all components for cracks or damage. Confirmed that all parts were intact and properly functioning. Reassembled and securely tightened the adapter fitting, then performed a leak check to verify proper seal and operation. Additionally, provided system overview and answered operational questions regarding the basement water care equipment at the homeowner's request. No leaks detected upon completion of repair.
Responded to no cooling complaint on 1999 air conditioning system. Upon inspection, found evaporator coil completely blocked with pet hair and dander, restricting airflow and preventing adequate cooling performance. Thoroughly cleaned evaporator coil, removing all debris accumulation. System tested after cleaning showed 18° temperature split across coil, indicating improved but potentially marginal refrigerant charge. Unit now cooling adequately with restored airflow; however, given age of equipment and slight concern about refrigerant levels, system may require future monitoring or refrigerant adjustment if cooling performance degrades.
Responded to a water leak in the basement caused by a frozen outdoor lawn faucet. Upon inspection, confirmed the frost-free sillcock had sustained freeze damage during winter conditions, resulting in internal component failure and active water intrusion into the basement space. Removed the damaged lawn faucet assembly and installed a new frost-free sillcock unit, ensuring proper pitch for drainage and secure mounting to the exterior wall framing. Tested the new installation for proper operation and verified no leaks were present at the connection points or through the valve body.