We’ve assisted homeowners for over 65 years and will proudly service your home as well.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Lakeville offers lots of ways to enjoy outdoor winter activities, like skiing at Buck Hill or ice fishing at Lake Marion. When you’re at home, you want to be warm and cozy, which requires having a fully functional heating system. Our heating services ensure you have the right heater for your house and that it works perfectly day in and day out. For added value, our maintenance services are crucial to boosting the performance of your heater and achieving lower heating costs.
Our Heating Services Ensure a Warm, Happy Home:
- Heating repair: Is the heater making strange noises? Do you notice a weird smell similar to rotten eggs? These are clues of major heating problems that we can fix.
- Heating installation: Get the best heater possible for your home’s unique heating needs with our expert installation care. Let us help you decide whether your home needs supplemental heating to stay warm during the coldest weather conditions.
- Heating maintenance: Save money on heating costs with our Hurlburt Family Rewards Program. You’ll receive annual heating maintenance, and up to $1,000 of your membership fees can go toward a heater replacement.
There’s so much to do outdoors during the summer in Lakeville. You can go swimming at Lake Marion, play tennis at Lakeville Area Tennis Courts, or even do long hikes at Ritter Farm Park. At home, to keep your living spaces cool and comfortable, you’ll need regular cooling services. Our technicians are experts in fixing refrigerant leaks, faulty compressors, and everything in between. With our services, your AC will not only last longer but also help you enjoy lower cooling costs.
Professional Cooling Services When You Need Them:
- Cooling repair: Don’t let refrigerant leaks and dirty filters compromise your home’s climate control. Instead, let us perform repairs to keep your AC working with optimal efficiency and performance.
- Cooling installation: Install the best cooling system for your home with our extensive installation support. We can even help you decide whether to go ductless.
- Cooling maintenance: Boost the performance of your AC and help it last for years to come by being a member of our Hurlburt Family Rewards Program. You’ll receive annual cooling maintenance, and up to $1,000 of your membership fees can help cover the cost of a new AC.
See all of our HVAC services in Lakeville.
Your plumbing system impacts your daily life in many ways, like how you wash clothing, how you do the dishes, and even how you take a bath. Even the smallest of leaks can lead to expensive water damage and major inconveniences. We can stop leaks in their tracks and keep your house watertight.
See all of our plumbing services in Lakeville.
Hazards like electrical shock and equipment damage make working with electrical systems very risky. For this reason, you should always hire a professional when dealing with electrical work. Our electricians here at Hurlburt have more than 65 years of industry experience. We are here to ensure your home has the safest electrical system possible.
There’s so much to do in Lakeville. Antlers Park gives you lots of outdoor activity options, like swimming, hiking, picnicking, and fishing. After spending the day enjoying the city, it’s important that you have a comfortable home to return to. That’s why we deliver the best HVAC, plumbing, and electrical services available in the city.
When it comes to home service providers in Lakeville, Hurlburt is among the most dependable. To find out why we are the go-to choice for so many homeowners, just look at our over 6,000 5-star ratings. We guarantee the highest quality HVAC, plumbing, and electrical services, thanks to our 65+ years in the industry.
We can fix that dripping faucet or even install a whole new HVAC system. When you compare us to other local home service teams, we stand out due to the exceptional quality of our work. Our unwavering goal is to ensure that every client has an exceptional experience.
Contact Hurlburt today to schedule an appointment with the best electrical, plumbing, and HVAC company in Lakeville!
Responded to no-cool call after electrical arc incident occurred during customer's cleaning of outdoor condensing unit. Upon arrival, assessed system and electrical components for damage, verified proper connections, and assisted with reassembly of unit housing and panels. Confirmed system operational with normal fan operation and proper startup sequence.
Responded to exterior faucet leakage issues affecting two hose bibs. Upon inspection, identified active leaking from backflow preventer assembly on primary spigot, causing rust staining on brick facade and moisture infiltration at foundation level. Removed malfunctioning hose attachment and backflow device from leaking unit. Evaluated second exterior faucet for similar wear and potential failure points. Addressed immediate water intrusion concerns to prevent further structural damage to masonry and interior basement walls.
Responded to water leak complaint originating from upper level and affecting lower level of residence. Investigated bathtub area as suspected source based on previous repair history. Identified loose toe kick stop as cause of leak. Tightened toe kick stop to resolve issue and stop water intrusion.
Completed routine A/C maintenance on Bryant condensing unit as part of preventative maintenance agreement. Performed comprehensive system inspection including filter evaluation, thermostat operation, temperature differential across evaporator coil, condenser unit components, evaporator and condenser coils, blower motor, capacitors, compressor operation, R-410A refrigerant charge, and condensate drain line. Homeowner installed new 20x25x4 filter prior to service. Ambient temperature recorded at 78°F during service call. Static pressure readings indicated system may be slightly low on refrigerant charge; however, suction line pressure readings within acceptable range for current operating conditions. System achieving adequate temperature drop and cooling performance at time of inspection. Recommended continued monitoring of system cooling efficiency and operation. Unit operating normally with no immediate repairs required. Provided estimates for potential future service needs.
Assessed triple-basin commercial sanitizer sink with deteriorating drain basket strainers and gasket rings. Initial replacement parts were incompatible with existing fixtures. Documented existing plumbing configuration including PVC drainage system and sink drain assemblies. Provided bid for complete replacement of all three sink basket strainers with proper specifications.
Responded to service call for leaking outdoor hose bibb and kitchen plumbing issues. Replaced faulty washer component on exterior spigot, resolving the leak at the hose bib connection point. Completed full replacement of kitchen faucet at double-basin undermount sink. Documented completed installations with photographs showing properly functioning exterior spigot with attached garden hose and updated kitchen faucet fixture.
Performed comprehensive air conditioning tune-up on 8-year-old system. Tested and verified refrigerant charge levels within proper range. Inspected and tested compressor, fan motor, and contactor—all components operating within specifications. Identified failing capacitor reading out of acceptable range and replaced with new unit. Confirmed air conditioning system fully operational following capacitor replacement. During routine inspection, discovered cracked heat exchanger in furnace located past the high limit switch, rendering the heating system unsafe for operation. Tagged furnace as inoperable due to safety hazard. Initiated warranty verification process for heat exchanger replacement and scheduled follow-up appointment to provide repair estimate and discuss furnace replacement options.
Responded to warranty service call for two mini split indoor units leaking condensate onto flooring. Found both drain lines completely obstructed with black sludge and debris buildup. Manually drained water from smaller head unit and cleared blockage from larger head by blowing CO2 through drain line from basement access point, removing significant accumulation of organic matter. Verified proper drainage restored to both units with no further leakage from drain pans. Recommended preventative maintenance tune-up to avoid recurrence of drain line blockages.
Responded to no cooling complaint on 5-year-old residential AC system. Upon inspection, diagnosed failed capacitor and low refrigerant charge as root causes preventing proper cooling operation. Replaced defective capacitor and recharged system to manufacturer specifications, restoring full cooling functionality.
Responded to commercial kitchen for reported draining issues on three-compartment stainless steel sink. Upon inspection, identified that drain gaskets in two compartments were not properly seated, causing one basin to fail to hold water and another to drain excessively despite stopper being engaged. Adjusted and reseated gaskets in both affected compartments to restore proper function. Documented current condition and provided bid for future replacement of drain assembly components.
Responded to no cooling complaint on 15-year-old Ruud air conditioning system. Diagnosed system low on refrigerant with active leak present. Measured temperature split at 16 degrees across coil, indicating inadequate cooling capacity. Evaporator coil temperature reading of 34 degrees approaching freezing point due to low refrigerant charge. Verified air filter clean, evaporator coil clean, and blower operating at correct fan speed. Discussed repair and replacement options with homeowner and provided written estimates via email. Scheduled follow-up appointment with service advisor to finalize solution.
Responded to report of water leaking into sump pump when underground sprinkler system was activated. Upon inspection, identified burst copper pipe in water line supplying backyard faucet. Turned on shut-off valve to confirm leak location, observing water discharge from wall cavity. Cut access opening to expose damaged section of copper piping. Removed compromised pipe segment and installed new copper section secured with two couplings. Pressure tested repair by restoring water supply and monitoring for ten minutes with no leaks detected. Restored backyard faucet to full service, secured access point, and completed site cleanup.
Responded to no cooling complaint on 11-year-old air conditioning system. Upon arrival, found unit not running due to low pressure safety switch activation. Bypassed low pressure switch to perform diagnostic testing of refrigerant levels. Encountered seized low side service port locking cap that could not be removed; obtained pressure readings from high side service port only. Readings confirmed system is significantly low on refrigerant charge. Identified refrigerant type as obsolete R-22, which is no longer manufactured and has limited availability at premium cost. Used digital multimeter to verify electrical components and capacitor operation within acceptable parameters. Accessed outdoor condenser unit and inspected internal wiring, contactor, and run capacitor - all components functioning properly when power supplied. Confirmed compressor attempts to run when low pressure safety is bypassed, indicating mechanical components operational but insufficient refrigerant charge preventin
Conducted site assessment for commercial espresso machine installation, evaluating existing utility room infrastructure and plumbing access points. Provided estimate for water supply line and drain line installation to accommodate espresso equipment, as well as water softener system integration to protect the machine from mineral buildup and ensure optimal beverage quality.
Responded to no cooling call on 1-2 year old Lennox heat pump system. Upon arrival, performed diagnostic inspection and found low refrigerant levels. System was operational but running with reduced cooling capacity. Checked refrigerant charge and identified deficiency requiring attention. Inspected indoor air handler unit and outdoor condenser components, documenting system condition with photos of control panel wiring and indoor equipment. Advised customer on proper air filter maintenance schedule due to presence of multiple pets in home, as inadequate filtration can lead to reduced airflow and system efficiency issues.
Responded to no cooling complaint on 5-year-old Bryant air conditioning system. Customer reported outdoor fan making abnormal noise indicating potential failure. Upon inspection, diagnosed failed dual run capacitor causing improper compressor and condenser fan motor operation. Removed defective capacitor and installed new dual run capacitor to manufacturer specifications. Tested system operation, confirmed proper compressor startup, verified condenser fan motor running at correct speed, and validated normal cooling cycle restoration. Unit returned to full operational status.
Responded to no cooling complaint on dual-zone system affecting upper level with both units inoperative. Found extensive ice formation throughout refrigerant lines extending from evaporator coil to outdoor condenser unit. Outdoor condenser coil heavily plugged with debris restricting airflow. Cleaned condenser coil thoroughly to restore proper airflow. Instructed homeowner to operate system in fan-only mode to allow complete ice thaw. Recommended retesting system operation after 24-hour thaw period and follow-up service call if cooling issues persist.
Responded to no cooling complaint on two-month-old dual-zone Lennox system. Upon arrival, found one condensing unit non-operational due to failed condenser wire connection. Ran new electrical wire to affected unit, restoring power and operation. Tested both systems and confirmed proper function. Identified restricted airflow issues caused by closed vents throughout home and dirty air filters requiring replacement. Cleared airflow error codes after verifying both outdoor units operating correctly with adequate refrigerant charge and proper electrical supply.
Responded to no cooling complaint on 16-year-old Lennox heat pump system experiencing intermittent operation. Diagnosed failed ECM condenser fan motor as cause of cooling failure. Provided repair option estimate via email for motor replacement. Given unit age exceeds typical 15-year lifespan, scheduled system replacement estimate appointment.
Responded to service call for leaking outdoor backflow preventer located near AC unit. Upon inspection, identified compromised Watts backflow device with active water leak. Assessment revealed missing plug component from previous winterization/blow-out service performed by irrigation company. Documented existing plumbing assembly configuration including pressure regulator, multi-valve manifold system, and backflow prevention device mounted on exterior access panel. Provided estimate for repair options and advised homeowner of requirement to obtain HOA approval prior to proceeding with any modifications to the backflow system.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions | [cookie_preferences_link]
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.