The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to no water pressure complaint on shallow well jet pump system. Upon arrival, performed diagnostic testing on blue horizontal pressure tank assembly and pump motor. Verified pressure switch operation was within normal parameters and confirmed pump remained primed with no loss of suction. Inspected and tested check valve functionality - found to be operating correctly. Conducted systematic troubleshooting to isolate cause of water supply failure. Diagnostic meter readings and visual inspection indicated pump motor failure as primary issue. Determined well running dry as secondary possibility but assessed as unlikely based on system conditions. Documented equipment configuration including pressure tank, pump assembly, gauge readings, and piping connections with photographic evidence. Recommended pump replacement to restore water pressure and system functionality.
Responded to no cooling complaint on a 2-year-old Honeywell zoned HVAC system where the main floor thermostat was unresponsive to setting changes, remaining at 74°F regardless of input. Upon inspection, found the system operates a multi-zone configuration with separate upstairs and main floor zones connected by an open stairway, with the main floor thermostat located at the base of the stairs. Diagnosed primary issue as improper zone management rather than equipment failure—upstairs zone set at 72°F was affecting main floor temperature control due to open air circulation between levels. Additionally identified secondary mechanical issue with 8x8 zone damper experiencing excessive bypass air and slow actuation response, contributing to temperature control difficulties. Educated homeowner on proper thermostat operation strategy, recommending adjustment of upstairs thermostat settings during the day to achieve desired main floor temperatures. Provided estimate for replacement of malfuncti
Responded to water leak in basement originating from hose bib fitting connected to main bathroom plumbing. Upon inspection, identified failed hose bib and compromised pipe section in basement ceiling area near mechanical room. Removed defective hose bib and damaged pipe section. Installed new hose bib with proper fittings and replaced affected copper piping to ensure secure, leak-free connections. Tested system under full pressure to verify repair integrity and confirmed no further water intrusion. Documented conditions with photos showing basement infrastructure, water heater area, and repair location for service records.
Responded to service call for low refrigerant charge on R410A system. Added refrigerant per previously provided estimate, including proper level adjustment to manufacturer specifications. Verified system operation with 16° temperature split across evaporator coil. Added UV dye to system for future leak detection if needed. Confirmed all parameters within normal operating range upon completion.
Completed warranty replacement of electric water heater in unfinished basement utility area. Removed failed unit and installed new water heater, including all necessary connections to existing copper supply lines and electrical service. Installation included proper connection of temperature and pressure relief valve, securing all hot and cold water connections, and disposal of old unit per manufacturer warranty requirements.
Replaced failed condenser fan motor and capacitor on outdoor air conditioning unit. Upon completion, tested system operation to verify proper functionality and airflow.
Responded to report of toilet leaking extensively in residential bathroom. Upon assessment, determined that existing toilet had developed persistent leak requiring full replacement rather than repair. Removed old two-piece toilet fixture, including disconnecting water supply line and unbolting from floor flange. Inspected flange and subfloor for water damage; confirmed structural integrity. Installed new ADA-compliant toilet to meet customer's accessibility requirements and height preferences. Secured new fixture to flange with brass closet bolts, installed new wax ring seal, and reconnected chrome water supply line. Tested for proper function and verified no leaks at base or supply connection. Left work area clean with all old materials removed from premises.
Responded to no cool call on 22-year-old system with frozen evaporator coil and suction line frozen back to compressor. Diagnosed significant refrigerant leak with system pressure at 80 psi versus expected 180 psi at equalization. Recommended system replacement due to age and extent of repairs needed, with sales advisor scheduled to provide equipment quote.
Responded to callback for loose toilet seat on left side. Inspected installation and hardware connections, verified proper mounting and tightness of bolts. Seat tested and functioning correctly with no movement detected. Customer sat on seat to verify stability and confirmed satisfaction with repair.
Responded to callback for water accumulation under recently installed furnace and moisture spots on basement drywall. Upon inspection, found no leaks from HVAC system components or condensate lines. Investigation revealed failed sealant around lineset penetration at exterior wall, allowing rainwater infiltration. Water traveled through lineset insulation and dripped at furnace location. Removed old silicone and properly sealed exterior penetration to prevent further water intrusion.
Responded to a leak at the pressure tank assembly caused by a pinhole leak on the elbow joint connected to the tank. Upon inspection, identified the compromised copper bend and deteriorated tank tee fitting as the source of the water loss. Replaced the defective tank tee with a new brass fitting and repaired the affected section of copper piping using proper soldering techniques. Tested the pressure tank system for leaks and verified proper operation of all valves and connections. System restored to full functionality with no active leaks detected.
Returned to service PTAC unit that was not cooling following power utility repairs to external service line. Upon arrival, verified proper voltage now present at unit but system completely unresponsive. Diagnosed failed capacitor preventing compressor and fan operation. Replaced defective capacitor with new component per manufacturer specifications. After installation, compressor experienced delayed start-up, requiring extended run time before engaging. Cycled system multiple times to verify operation; unit eventually achieved consistent start-up and began cooling properly. Noted potential intermittent control board or compressor issue based on delayed engagement behavior. Advised customer that if starting problems recur or compressor fails to engage reliably, complete PTAC replacement may be more cost-effective than additional component repairs. Confirmed unit running and producing cool air at time of departure. Recommend monitoring system performance and reporting any further startin
Responded to no cooling complaint on 24-year-old R22 system. Found compressor failing to start at outdoor condenser unit. Discovered and removed mouse nest from condenser, inspected all wiring and confirmed no rodent damage. Attempted multiple starts; compressor eventually engaged but exhibited slow, labored startup indicating internal wear. Tested run capacitor, reading 27.8 µF on 30 µF rated capacitor—slightly low but within acceptable range to start compressor under normal conditions. Explained to homeowner that while capacitor replacement was an option, the compressor's hard-start behavior suggested internal mechanical failure likely due to age, and repair may only provide temporary relief. Discussed system age, obsolete R22 refrigerant, and reliability concerns. Homeowner elected to pursue full system replacement rather than invest in repairs on aging equipment. Scheduled replacement consultation.
Responded to service call for leaking water heater with no hot water. Upon inspection, found AO Smith water heater originally installed in 2021 experiencing active leak from element port area with visible water pooling at base and significant rust staining on lower tank section. Confirmed unit is still under manufacturer warranty valid through 2027. Documented blowout condition at element port with photographs showing corrosion damage and water accumulation. Determined warranty replacement is required due to tank failure. Unable to complete replacement on initial visit as parts supplier was closed for weekend. Scheduled return appointment to install warranty replacement water heater once new unit is obtained from supplier.
Responded to emergency call for leaking 1-inch PVC pipe in pool room mechanical area. Upon arrival, identified active leak at 90-degree elbow joint on non-potable water inlet line. Shut off water supply, removed failed PVC 90 fitting, and installed new elbow with proper primer and solvent cement. Utilized rubber coupling connectors to ensure secure, watertight seal at pipe joints. Restored water flow and pressure-tested all connections to verify complete leak elimination with no further dripping or seepage detected.
Responded to no hot water complaint on propane-fired tankless water heater displaying error code 29. Upon inspection, discovered extensive moisture on pipes surrounding unit and significant water intrusion inside cabinet. Internal components showed corrosion damage consistent with lack of preventative maintenance. Attempted troubleshooting procedures for error code 29 without successful resolution. Confirmed unit had never received manufacturer-recommended annual servicing during its operational lifespan. Due to combination of corrosion damage, out-of-warranty status, and absence of maintenance history, recommended full unit replacement rather than repair. Documented unit condition with photographs of manufacturer data plate and installed equipment. Coordinated follow-up estimate appointment for replacement options.
Responded to service call for Noritz NR98-DVC tankless water heater displaying error code 14, indicating flame failure or combustion issues. Upon inspection, determined unit is over 12 years old and has never been flushed, resulting in significant hard water mineral buildup in the heat exchanger restricting flow and causing unit shutdowns. Provided estimate for descaling flush service to remove calcium deposits and restore proper operation. Advised that if flushing does not resolve the issue, heat exchanger replacement or full unit replacement may be necessary due to age and condition of equipment.
Responded to no cooling call on 41-year-old residential air conditioning system originally installed in 1985. Found tripped breaker at outdoor unit and measured excessive amperage draw on compressor circuit using digital multimeter. Reset breaker temporarily to verify system operation, but compressor continued to draw high amps indicating internal failure. Comfort advisor appointment was already scheduled for same day to discuss system replacement options due to age and failed compressor.
Performed comprehensive inspection of 1991 pulse furnace and 2010 air conditioning system to assess equipment condition and replacement needs. Conducted pressure test on pulse furnace combustion system, verified all routine components, cleaned outdoor condenser unit, and tested AC electrical components and operation. All equipment tested and operating within normal parameters at time of inspection.
Responded to service call regarding sump pump cycling frequently without rainfall. Upon arrival, observed sump pump operation while water softener was in recharge cycle. Inspected sump pit and drainage system, noting at least six discharge lines including dehumidifier line draining into floor drain adjacent to sump pit. Monitored pump performance through multiple cycles and found no mechanical abnormalities with pump operation, float switch, or discharge line. Explained to customer that increased cycling frequency was due to combined water discharge from dehumidifier operation during current humid weather conditions and water softener regeneration cycle, both contributing significant water volume to drainage system. Pump functioning as designed under increased load conditions.