Since 1959, Hurlburt has made it our mission to keep your home comfortable and protected.
Enjoy a cool, comfortable home during the hotter months in Bloomington with expert air conditioning services. At Hurlburt, we specialize in keeping your home comfortable. We service all makes, models, systems, and configurations of ACs, whether a central AC unit, ductless mini-split, or heat pump. When upgrading your current cooling system, we’ll help you pick the perfect energy-efficient replacement that fits your needs and budget.
What signs indicate you need AC repair? If your AC is blowing warm air, there’s excess humidity indoors, or the system is cycling on and off frequently, it’s time to call our technicians for repair services. We’ll quickly diagnose and rectify any issue you’re dealing with. Plus, we’ll recommend routine maintenance to help avoid repairs in the future and keep your AC running efficiently.
See our specific HVAC and IAQ services.
Our AC Services Exist To Meet Your Needs!
- AC Repair: Are you noticing issues like short cycling, your AC blowing warm air, or no air at all? Rely on our expert technicians for AC repair. We’ll arrive promptly to investigate and fix any cooling issue you’re experiencing.
- AC Installation: Most AC systems last 10-15 years, depending on maintenance and usage. However, when it’s time for AC replacement, you’ll want our pros on your side. We’ll walk you through each step of the installation process, providing you with budget-friendly, energy-efficient options.
- AC Maintenance: Keep your AC running optimally with expert routine maintenance from our technicians. As part of our Hurlburt Family Rewards Club, we’ll inspect, lubricate, and clean all parts of your AC to ensure it provides efficient, reliable service.
With cold, snowy winters, Bloomington’s climate requires homeowners to have a reliable heating system. That’s why we provide a full range of heating services to keep your home at the perfect temperature. No matter what type of system you have, whether furnace, boiler, or heat pump, we’ll ensure it provides you with years of efficient service. Ask us about heating maintenance!
When your heating system has unexpected issues, you don’t have to sacrifice your comfort. Our expert technicians can provide long-lasting repairs and innovative solutions for any problem. It’s all a part of our dedication to your comfort. When the time comes to replace your heating system, you can still rely on us. We provide precise installation of the highest-quality heating systems, partnering with industry-leading brands to provide the most energy-efficient options.
Trust our team to help you with heating projects of any size– call for a quote today!
Our Expert Heating Services Include:
- Heating Repairs: Don’t suffer in a home that’s too cold. Work with our expert technicians when you need effective heating repair. No matter what system you have, we’ll be able to service it. Our fast service will get you back into a comfortable home in no time.
- Heating Installation: Is your heating system past its prime? Work with the best team for your next installation. Our technicians will provide energy-efficient, budget-friendly options that perfectly fit your family’s needs.
- Heating Maintenance: No matter the weather outside, expert maintenance will keep your heating system working smoothly. Our Hurlburt Family Rewards Club provides comprehensive tune-ups for your system to ensure smooth operation and optimum comfort all year.
Whether your property is a sprawling farm or quaint historic townhome, Hurlburt is here to ensure your plumbing is never a headache. Our comprehensive services aim to ensure the comfort and cleanliness of your home so that you can focus on what truly matters.
We understand the hassle that leaks can cause, whether they’re from burst pipes or dripping faucets. That’s why our team provides leak detection and repair services that keep your water lines, gas lines, and pipes in excellent condition. We even handle your sewer and drain issues to keep wastewater safely flowing away from your home.
Got a frustrating water heater issue? Our team is one call away and can provide the necessary services to ensure you always have access to the hot water you need for daily tasks. Together with our water treatment services, we aim to keep your home running properly.
See our specific Plumbing services.
Contact Hurlburt to learn about our full range of plumbing installations, replacements, and repairs.
Electrical issues can pose serious safety risks, especially in Bloomington’s older homes. To ensure your space is up to code and provides sufficient power for your modern lifestyle, Hurlburt offers a wide range of electrical services.
From electrical panels to outlets, our primary goal is to keep your home safe from electrical hazards. We do this by ensuring that every component of your electrical system is operating properly and can handle issues that range from overloaded circuit breakers to frayed and damaged wiring.
Our team is committed to providing our customers with cutting-edge technology, including smart home automation and EV chargers. When combined with our energy-efficient upgrades, homeowners can have a modern household designed to tackle their 21st-century lifestyle.
Professional electrical services you can trust:
- Electrical Repairs: Keep your home’s electrical system in good hands with our repair services. Our electricians will inspect your electrical components when there’s cause for concern. We’ll pinpoint the exact problem and provide effective solutions that keep your lights shining and appliances running consistently.
- Electrical Installation: Looking to increase your home’s electrical capabilities and convenience? Look to our electricians for your next electrical installation. Whether you want an EV charger installed at home, updated outlets, a backup generator, or more, we’ll be there to transform your living space.
Hurlburt is proud to be a part of the communities we serve. That’s why we treat our customers like our own neighbors. We always provide you with honest, trustworthy advice and safe services that keep your Bloomington home operating at peak efficiency. With our personalized customer service and custom home solutions, we’ve earned our reputation for providing world-class service.
Family-owned and -operated Hurlburt stands apart from the competition with superior service, passion, and a client-centric approach. As a member of the Hurlburt family, our customers will always receive a world-class experience with innovative solutions that improve your day-to-day life. With more than 6000 5-star reviews, our reputation says it all.
Call Hurlburt today to schedule HVAC, electrical, or plumbing service for your Bloomington home.
Hurlburt Heating & Plumbing has completed 20 jobs in Bloomington, MN between August 2026 and September 2026.
The most recent job was on September 1, 2026.
Responded to no cool call on 21-year-old Lennox air conditioning system. Diagnosed and replaced failed blower capacitor to restore furnace blower operation. During troubleshooting, discovered tripped AC breaker; upon reset attempt, right side of breaker disengaged from bus rail. Temporarily reseated breaker but noted excessive looseness requiring electrical panel correction for safety. Performed comprehensive system evaluation including heat exchanger inspection (observed wear and potential crack formation at eyelets), refrigerant charge verification (within specifications), AC electronics testing (operational), and temperature drop measurement (within acceptable range). All photographic documentation completed. Customer enrolled in rewards program and follow-up appointment scheduled with service advisor for equipment age concerns and electrical panel issue.
Completed annual heating maintenance visit on one 2-year-old gas furnace and one heat pump system per maintenance agreement. Performed comprehensive heating system inspection including combustion analysis using Testo 310 II analyzer, which showed natural gas furnace operating at 95.0% efficiency with acceptable O2 levels at 5.9% and CO readings at 1.7 ppm. Conducted temperature measurements in attic space and inspected ductwork systems. All equipment found operating within normal parameters with no deficiencies noted or repairs required at this time.
Replaced the internal condensate pump and float switch assembly on the attic air handler unit. Disassembled the unit to access the condensate collection system, removed the failed pump and float mechanism, and thoroughly cleaned accumulated sludge from the condensate pan. Installed new pump and float switch, resealed all insulation connections, and tested the system to verify proper condensate removal and normal operation.
Diagnosed and assessed severely corroded cast iron mission band pipe system showing extensive rust damage and structural compromise. The existing pipe exhibited heavy oxidation with flaking layers and visible cracking throughout the affected section. Documented the deteriorated condition of the horizontal pipe run in the crawl space area, noting the advanced corrosion that had penetrated through multiple layers of the metal surface. Provided repair estimate for replacement of the compromised cast iron section with updated plumbing materials to restore proper function and prevent potential failure or water damage.
Completed bathroom plumbing installation in a condo unit including shower valve replacement with new isolation valves, toilet installation, and shower trim finishing. Lavatory faucet installation encountered issue with defective hot water valve requiring replacement parts to be sourced. Successfully installed new shower valve assembly with copper supply lines and shutoff valves during bathroom renovation phase, coordinating with building-wide water shutoff requirements.
Responded to callback for newly installed HVAC system not reaching setpoint of 69°F in upstairs zone. Upon inspection, discovered multiple airflow restrictions including closed dampers and registers in kids room, living room, guest bedroom, and both bathrooms. Found upstairs bathroom infloor heating systems active and set to 78°F, along with fireplace pilot flame producing excessive heat in close proximity to thermostat location. Opened all upstairs registers, closed downstairs registers to balance system, deactivated all infloor heating, and set fan to continuous operation. Educated homeowner on thermal conflicts between simultaneous heating and cooling operations and impact on system performance and thermostat accuracy. Verified unit operation and proper airflow distribution throughout conditioned space. Documented control board status and structural components with photos.
Responded to no cooling complaint on 10+ year old air conditioning system. Upon inspection, diagnosed failed blower motor as cause of inadequate airflow and system shutdown. Replaced defective blower motor with new unit and verified all other system components including compressor, condenser fan, and refrigerant levels were functioning within normal parameters. Tested system operation and confirmed unit is cooling properly and cycling correctly.
Completed annual cooling maintenance on two commercial rooftop units. Replaced twelve 20x25x2 return air filters. Found one unit's condenser coil heavily clogged with cottonwood debris, restricting airflow; thoroughly cleaned and restored proper airflow. Second unit's coil was in good condition. Performed comprehensive inspection on both units including electrical connections, load and control voltages, motor amp draws verified against full load ratings, and economizer function testing. Inspected cooling circuits and checked refrigerant levels—all within normal operating parameters. Verified fan motors, capacitors, and control boards functioning properly. Cleaned condensate drain pans and traps. Inspected belts and pulleys for wear. Both systems tested and operating efficiently for continued cooling season operation.
Responded to airflow concerns and performed comprehensive ductwork inspection using camera scope to identify potential blockages. Investigated hidden dampers concealed above ceiling tiles, opened closed dampers to restore proper airflow, and measured supply air temperatures at multiple registers, recording readings of 54.6°F and 59.8°F to verify system performance after adjustments.
Responded to no cooling call on 10+ year old Ruud R-22 system. Verified thermostat operation normal. Inspected outdoor unit and found contactor failed - confirmed 240V and 24V power supply present but no 240V output to compressor circuit. Replaced defective contactor and restored system operation. Initial temperature split measured only 7 degrees across evaporator coil. Identified heavily soiled air filter restricting airflow and replaced with new filter. Found outdoor condenser coil significantly clogged with dirt and debris. Performed coil cleaning by rinsing down outdoor unit. Rechecked temperature split after cleaning, which improved to 15 degrees, confirming restored cooling efficiency. System now operating within normal parameters.
Completed installation of dual basket strainers with kitchen sink repiping and customer-supplied faucet installation. Replaced existing drain assembly with new chrome basket strainers, installed white PVC P-trap configuration with proper compression fittings, and connected dishwasher drain line to disposal knockout. Installed new shut-off valves for hot and cold water supply lines and completed all connections to ensure proper drainage and water flow. All plumbing components were tested for leaks and verified operational upon completion.
Completed annual spring cooling maintenance on one residential air conditioning system utilizing 410A refrigerant with an ambient temperature of 74 degrees. Performed comprehensive inspection of indoor air handler including thermostat operation, air filter condition, condensate drain functionality, blower motor performance, and all electrical wiring and components with satisfactory results. Verified proper temperature split across the evaporator coil. Conducted thorough examination of outdoor condensing unit including coil cleanliness, capacitor condition, and measured amperage draws on compressor motor, fan motor, and contactor, all within manufacturer specifications. Confirmed proper refrigerant charge levels and overall system operation with no deficiencies noted.
Responded to a clogged toilet in a residential property. Successfully cleared the blockage using a plumbing auger to restore proper drainage and functionality. Toilet was tested and confirmed to be operating normally upon completion.
Responded to service call for kitchen sink leak and low water pressure issue in bathroom sink. Upon inspection, identified failed basket strainer assembly with significant corrosion and rust staining at threaded connections under kitchen sink. P-trap and tubular drain assembly showed deterioration with active leaking at multiple connection points. Replaced corroded basket strainer with new chrome unit, installed new PVC P-trap assembly and tubular drain connections. Tested all connections for leaks and verified proper drainage. Inspected bathroom sink faucet with black finish and two-handle configuration for reported low water pressure concern. Isolated issue to aerator blockage, cleaned and reinstalled. Confirmed adequate water pressure restored to bathroom faucet. All plumbing connections secured and leak-free upon completion.
Responded to service call for downstairs bathroom sink with severely reduced water flow. Upon inspection of the white wall-mounted sink with chrome cross-handle faucets, confirmed minimal water output from the faucet. Diagnosed issue as clogged aerator restricting water flow. Removed aerator from faucet spout, cleared debris and sediment buildup, and reinstalled aerator. Tested water flow and verified full pressure restoration to the fixture.
Responded to callback following city inspector's concern about potential plumbing leak in cellar. Conducted thorough inspection of all piping, including previously serviced hose bib backflow prevention device and main shut-off valve. Found no active leaks present; all previous repairs remain watertight and functioning properly. Observed significant condensation accumulation on cellar pipes throughout the space. Documented conditions with photographs showing ball valves, copper piping connections, and moisture presence on supply lines. Confirmed condensation is environmental issue related to temperature differential and humidity levels, not plumbing failure requiring repair.
Responded to no cooling call on residential air conditioning system. Upon arrival, found unit completely inoperative with no air movement from indoor blower. Inspection revealed electrical disconnect at outdoor condensing unit was not fully seated, interrupting power to system. Additionally, discovered heavily restricted air filter at furnace, significantly impeding airflow. Fully engaged disconnect switch to restore power and replaced dirty filter. Verified system startup with proper operation of both indoor and outdoor units. System now cooling normally with adequate airflow throughout.
Responded to water line break in bathroom shower system. Upon inspection, identified cracked copper tub spout arm at the bend joint, which had developed a failure point causing active water leakage. Created wall access opening to expose the plumbing assembly and assess the full extent of the damage. The copper pipe exhibited significant corrosion and oxidation, particularly concentrated at the U-bend section where the crack had formed. Removed the damaged tub spout arm and installed a replacement component. Verified all connections for proper seal and tested the system under full water pressure to confirm leak resolution and restore normal operation.
Responded to air handler fan relay malfunction where the blower motor continued running after the thermostat call ended. Replaced the defective fan relay and transformer relay to restore proper system operation. Cycled the equipment through fan-only mode and cooling mode to verify the blower motor now responds correctly to thermostat commands. System tested and confirmed operating within normal parameters. Additionally addressed fireplace insert issue where pilot flame was oversized, causing high-limit safety shutoff. Adjusted pilot flame to manufacturer specifications and verified proper burner operation without nuisance tripping.
Completed annual cooling maintenance on 2-year-old Lennox air conditioning system with Unico attic air handler. Performed comprehensive inspection including contactor testing, capacitor verification, and refrigerant charge assessment—all within manufacturer specifications. Cleaned outdoor condenser coil and verified proper amp draws across all components. Measured temperature drop at 18 degrees, confirming optimal system performance. Noted air filter requires replacement soon but system is operating efficiently with no deficiencies identified at this time.