Since 1959, Hurlburt has made it our mission to keep your home comfortable and protected.
Top-notch heating repairs, installations, and maintenance in Baldwin are a must during winter. However, they’re particularly necessary when temperatures drop below freezing. Without proper heat, your safety and well-being are in jeopardy. You can trust our team to help you get your home to the proper warm temperature.
Our comprehensive heating services ensure our clients can count on us when they need us most. Whether you want to replace an ageing system or you’re experiencing problems with your current one, we’re here to help with your heating repair in Baldwin. We provide standard repairs and emergency HVAC in Baldwin.
From performing ductless system installations to AC repairs in Baldwin, our HVAC technicians do it all. They pay close attention to detail to ensure your cooling system works properly for you, especially during the hottest days.
Cool, conditioned air is important for every home. However, it’s particularly crucial in houses with seniors, kids, and health-compromised individuals. We can make sure your system works perfectly and gets your home to your ideal temperature.
Our plumbers in Baldwin provide many types of services, including plumbing installations, gas line repairs, and water heater maintenance. Long-lasting plumbing solutions are essential, particularly in the kitchen and main bathroom. They help keep your home functioning optimally without disruption and help extend your system’s life span.
Plumbing issues are undoubtedly frustrating. The good news is that our team handles projects of all sizes, so you can feel confident we’ll address any situation efficiently.
Homeowners should never attempt electrical tasks on their own as this could risk their safety and home. Our electricians in Baldwin work on electrical projects of all sizes from outlet replacements to EV charger installations. Safety is a top priority no matter the scope and size of the job.
Hurlburt’s comprehensive electrical services make it easy to get the assistance you need as quickly as possible. Whether you’re planning a new build or living in an existing home, you can depend on us for a thorough, safe job.
Hurlburt proudly serves Baldwin homeowners, providing excellent electrical, HVAC, and plumbing services. Let us handle your home’s systems so you can focus on enjoying local restaurants, strolling in parks, or taking a drive to Willow River State Park.
Our family-owned and -operated company has been serving clients for over 65 years. We love what we do, and we hire experienced team members who take pride in their work. Over the years, we’ve helped multiple generations care for their homes and HVAC in Baldwin. We invite you to read our online reviews to learn more about what you can expect from teaming up with us. Welcome to the Hurlburt Family!
Schedule an appointment today with Hurlburt for assistance in plumbing, electrical, HVAC, and indoor air quality in Baldwin.
Hurlburt Heating & Plumbing has completed 20 jobs in Baldwin, WI between July 2026 and August 2026.
The most recent job was on August 13, 2026.
Replaced malfunctioning shut-off valve that was not fully closing water supply to toilet tank. Repositioned new angle stop valve to accommodate installation of American Standard toilet fixture in upstairs bathroom. Relocated existing toilet from upstairs to downstairs bathroom as replacement unit, then installed new American Standard toilet in upstairs location with proper clearance from repositioned shut-off valve.
Completed propane gas line hookup to new stove installation. Disconnected existing gas connection, installed new gas line to stove, and performed comprehensive leak testing on all fittings and connections to verify system integrity. All connections tested with no leaks detected, ensuring safe operation of appliance.
Responded to callback for dirty water accumulating in dishwasher following garbage disposal removal. Upon inspection, identified that dishwasher drain line lacked proper high loop configuration, allowing wastewater to siphon back into the appliance. Installed proper high loop on dishwasher drain line under sink to prevent backflow and ensure complete drainage from the line. Tested system to verify proper operation and drainage.
Responded to no cooling complaint on 22-year-old central air conditioning system. Upon arrival, confirmed outdoor condenser fan motor was experiencing delayed start and running at reduced speed, with unit blowing room temperature air through vents. Diagnostic testing revealed failed dual run capacitor on fan circuit, verified through multimeter readings showing capacitance outside acceptable range. Replaced defective dual run capacitor and confirmed proper amperage draw and voltage supply to compressor and condenser fan motor. System previously diagnosed as low on R410A refrigerant charge during earlier service visit. Restored system to operational status with condenser fan motor starting immediately and running at proper speed.
Completed Family Rewards annual cooling maintenance visit on residential air conditioning system. Performed comprehensive tune-up including inspection of outdoor unit electrical components, capacitor, contactor, and wiring connections; all components found operational with normal age-related weathering noted. Indoor furnace and HVAC system inspected with gas connections, ductwork, and filtration systems verified in proper working order.
Responded to no cooling call on 27-year-old central air conditioning system. Upon arrival, found outdoor condenser unit buzzing but not running, with breaker tripped. Reset breaker and performed diagnostic testing on all major components. Compressor attempted to start but failed to run, drawing high amperage during start attempts. Installed hard start capacitor to assist compressor starting, but unit still failed to operate properly. Compressor determined to be mechanically failing and unable to achieve full operation even with hard start assistance. Due to age of system and extent of compressor failure, provided customer with options for replacement system pricing alongside repair estimates for next steps decision.
Performed routine cooling maintenance on a 28-year-old air conditioning system as part of scheduled Family Rewards membership visit. Upon inspection, discovered dual capacitor and contactor showing signs of failure with visible corrosion, and compressor drawing higher than normal amperage. Due to the age of the system and multiple failing components, recommended comfort advisor consultation to discuss repair versus replacement options.
Responded to service call for leaking outdoor spigot and multiple plumbing issues. Upon arrival, identified failed hose bibb requiring replacement, leaking shower strainer seal, and defective check valve on sump pump line. Replaced deteriorated outdoor hose bibb with new unit to eliminate exterior leak. Installed new check valve on sump discharge line to prevent backflow. Replaced worn seal on shower strainer to stop water intrusion. All components tested and verified leak-free upon completion.
Completed AC maintenance visit on a 20 year-old system. Unit is currently cooling but found refrigerant levels low and capacitor reading out of acceptable range. Documented equipment make, model, and serial numbers with photographs per service agreement requirements. Advised customer that the out-of-range capacitor can lead to compressor failure and reduced system efficiency. Customer acknowledges system age and condition, opting to defer replacement until complete system failure occurs.
Responded to no cooling complaint on 1997 Lennox R-22 air conditioning system matched with older 80% gas furnace. Upon arrival, found system running but not cooling effectively. Performed diagnostic testing and identified failed dual run capacitor rated 35/5 µF reading 0/0 µF on both terminals. Tested compressor windings which showed open line to ground, confirming no ground short present at time of inspection. Replaced failed dual run capacitor to restore system operation. Following repair, verified system performance with temperature measurements showing 77°F return air and 58°F supply air, producing acceptable 19°F temperature split across evaporator coil. System restored to operational status with adequate cooling capacity at time of departure. Advised homeowner that due to system age (26 years old), obsolete R-22 refrigerant phase-out, and overall equipment condition, this repair should be considered temporary. Noted exterior disconnect panel showing significant rust and corrosi
Responded to callback regarding reported water backing up into dishwasher. Conducted thorough inspection of dishwasher drain line and kitchen sink drainage system. Ran multiple test cycles on dishwasher and kitchen sink to attempt to replicate the backup issue reported by customer. All drainage functioned properly with no backup observed during testing. Dishwasher drained completely without obstruction, and sink drainage operated normally with no water entering dishwasher. Unable to replicate the reported problem during service visit. Documented conditions with photographs for service records.
Performed comprehensive maintenance inspection on R22 air conditioning system and air exchanger unit. During efficiency and reliability assessment, identified elevated refrigerant levels and capacitor reading outside acceptable range. Completed system cleaning of outdoor condensing unit and indoor components. Verified air exchanger operational status and confirmed filter condition satisfactory. Presented repair options for identified deficiencies, and homeowner elected to receive formal estimate for necessary AC repairs to address refrigerant overcharge and capacitor replacement.
Responded to water leak originating from top floor tub/shower causing damage to first floor below. Upon inspection, identified source of leak at slip nut connection on 1-1/2" tub waste and overflow assembly. Removed and replaced defective tub waste and overflow unit. Resealed all joints and connections to ensure watertight installation. Tested system for proper drainage and verified leak was fully resolved with no further water intrusion to lower level.
Completed installation of customer-provided kitchen sink, faucet, and garbage disposal hookup. Prior to installation, relocated electrical conduit to accommodate proper sink placement. Successfully connected all plumbing fixtures and verified proper drainage and water flow upon completion.
Responded to no cooling complaint on residential air conditioning system. Upon inspection, diagnosed low refrigerant charge on R22 system. Verified filter and evaporator coil condition were acceptable. Measured inadequate cooling output and confirmed refrigerant deficiency in outdoor Goodman condensing unit. Due to R22 phase-out and system age, scheduled comfort advisor appointment to provide system replacement estimate rather than recharging obsolete refrigerant.
Disconnected all plumbing connections in kitchen to facilitate new countertop installation, including water supply lines and drain lines for sink, dishwasher, and refrigerator. Shut off appropriate water valves and electrical circuits at breaker panel to ensure safe working conditions during cabinet and countertop removal. Follow-up service scheduled to reconnect disposal and complete plumbing hookups after countertop installation is finished.
Removed and disposed of damaged concrete flooring to access failed drainage plumbing system. Extracted and disposed of deteriorated drainage pipes, then installed new plumbing pipe and fittings to eliminate the leak. Patched concrete floor, cleaned the work area, and performed pressure testing to verify leak-free operation with 1-year parts and labor warranty included.
Responded to a no cooling call on a 10+ year old residential air conditioning unit. Upon inspection, diagnosed a failing contactor causing the system malfunction. Replaced the defective contactor with new component, cycled the unit multiple times to verify proper operation and consistent starting, and confirmed improved system performance with reduced operational noise.
Responded to emergency call for burst pipe in basement with water leak detected within wall cavity. Upon inspection, identified failed drain piping below floor level as source of water intrusion. Documented existing conditions with photographs and provided detailed estimate for complete drain pipe replacement to resolve the issue.
Responded to no cool call on 10+ year old Comfortaire mini split system displaying CH-26 error code indicating compressor positioning fault. Performed diagnostic testing including verification of all electrical connections, compressor winding continuity tests, and coil inspection. All connections were secure with no corrosion present, compressor windings tested within normal parameters, and coils were clean. Diagnostics revealed failed inverter board as root cause of malfunction. Reviewed repair options with customer and scheduled follow-up service advisor appointment to discuss replacement recommendations.