We’ve assisted homeowners for over 65 years and will proudly service your home as well.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Winters in Apple Valley can sometimes bring temperatures well below zero. Your heater must be in prime shape to keep your family warm and comfortable. Our heating services include installation, maintenance, and repairs for all makes and models. We also provide electric and gas furnaces, boilers, and heat pump services. Our professional HVAC company ensures your heating system works safely and effectively.
See our specific HVAC and IAQ services.
Learn About Our Heating Services Below:
- Heating Repair: A heater breakdown in the middle of winter brings great stress. Our team guarantees all services to ensure your peace of mind.
- Heating Installation: Installing a new heating system can help combat winter’s cold more efficiently and reduce costs. Let us help you select the best system size and type.
- Heating Maintenance: Regular tune-ups are essential for keeping your heater working safely and effectively. We recommend scheduling annual maintenance. You can join our Hurlburt Family Rewards Program, which offers an annual comprehensive safety inspection.
Although our summers stay milder than our neighbors’ in the South, temperatures get warm enough to require air conditioners in Apple Valley. Our HVAC company offers installation, maintenance, and repair services for all makes and models, including Lennox and Trane. We handle all the services your air conditioner needs to work safely and efficiently.
Our Cooling Services Keep Your Air Conditioner Operating Efficiently
- Cooling Repair: Repair issues can occur without warning, but there are often telltale signs. If your air conditioner makes strange noises, we are here to help. Our expert technicians will restore your AC’s function.
- Cooling Installation: If your old system cannot keep up with cooling demands, it may be time for a new one. A new air conditioner brings welcome relief from the heat and can save you money. We help you through each step of the installation process.
- Cooling Maintenance: Your air conditioner needs maintenance to work safely and effectively. We recommend scheduling maintenance annually, usually in early spring. Join the Hurlburt Family Rewards Program to gain perks on services.
Most of your plumbing system is under your foundation, flooring, or behind walls or ceilings. Annual plumbing inspections help protect your home against unwanted leaks and other problems. We offer plumbing services that include installation, maintenance, and repair. As a trusted plumber in Apple Valley, we ensure your plumbing system operates effectively.
See our specific Plumbing services.
Most people rely on their electrical systems more than they realize, and power disruptions can disturb your family’s routine. Hurlburt works to protect your electrical system. Our electricians have advanced training and tools to handle all electrical needs, regardless of scope. From installation to repairs, we can handle any electrical job.
Reliable Electrical Services in Your Neighborhood
- Electrical Repair: Electrical issues can be dangerous and lead to fires or electric shock. Don’t ignore the signs of problems, including hot outlets and switches. Our electricians offer repairs for all electrical components, including breaker panels.
- Electrical Installation: Electrical installation services require a professional to ensure safety and code compliance. We install wiring, EV chargers, whole-home generators, and panels. Our electricians provide installation services for remodels, upgrades, and new construction.
You have probably seen our brightly colored vans driving up and down Highway 35E or Cedar Avenue. If you see us having lunch at Valley Dinner, don’t be too shy to say hello. We love serving our customers and the community of Apple Valley. Our team works hard and gives back as often as possible. We are a trusted HVAC company that offers plumbing and electrical services. We always hope you smile when you see our big red building!
Welcome to the Hurlburt Family! Hurlburt is here to help you make the best decisions for your home and family. We provide HVAC, plumbing, and electrical system installation, maintenance, and repairs. Hurlburt has proudly served our customers since 1959. We care about our customers and believe our services make a difference in the lives of residents in Apple Valley. Our team puts our customers first in every service we provide, and no job is too big or small.
Call Hurlburt when you need a professional plumbing, electrical, and HVAC company in Apple Valley. Our friendly team will help you schedule any of our home services.
Responded to no cooling complaint on 11-year-old residential air conditioning system. Upon arrival, confirmed unit was blowing warm air with no visible condensation at outdoor unit. Verified thermostat was properly calling for cooling mode. Performed comprehensive diagnostic inspection of outdoor condenser unit including visual examination of coil condition, capacitor operation, and refrigerant charge level. System found to be significantly low on refrigerant. Proceeded to indoor air handler where evaporator coil was discovered to be partially iced up, consistent with low refrigerant charge. Based on ice formation pattern and refrigerant loss, diagnosed probable refrigerant leak in system. Homeowner reported that another HVAC contractor had previously added 4 pounds of refrigerant to system, confirming ongoing leak issue. Presented repair options including leak detection dye injection and refrigerant recharge to temporarily restore cooling operation. Homeowner declined repair services
Responded to no cooling call on 23-year-old Goodman air conditioning system. Found frozen refrigerant lines at outdoor condenser unit and confirmed system was low on R22 refrigerant. Advised customer that R22 is no longer stocked due to phase-out regulations and recommended contacting a service provider who still services legacy refrigerant systems. System was shut down to prevent compressor damage from continued operation while frozen. Documented equipment condition with photos of outdoor condenser unit and indoor furnace components.
Performed annual backflow prevention testing on irrigation system's pressure vacuum breaker (PVB) assembly as required by municipal water authority. System had been shut down by the city pending compliance testing. Completed full diagnostic test of the PVB, replaced the backflow prevention device, conducted verification testing to ensure proper operation, and affixed certification tag indicating successful inspection and compliance with local water safety regulations.
Completed comprehensive AC tune-up on 3-year-old residential air conditioning system. Performed thorough cleaning and inspection of all components, measured electrical amperage with clamp meter to verify proper operation, and inspected outdoor condenser unit. System operating within normal parameters with no deficiencies identified. Advised customer to rinse condenser coils after cottonwood season to maintain optimal airflow and efficiency.
Completed annual cooling maintenance visit on 25-year-old Goodman AC system. During tune-up inspection, identified system operating with low refrigerant charge of obsolete refrigerant type. Documented equipment condition with photos showing furnace and associated utility connections. Provided repair options to customer via email and scheduled estimate appointment for new AC or heat pump replacement system due to age of existing equipment and refrigerant obsolescence.
Responded to service call for leaking hose bibs and loose water shut-off valve. Upon inspection, identified loose packing nuts on all three exterior hose bibs causing water seepage. Tightened packing nuts on each hose bib to proper torque specification, eliminating leaks. Inspected water shut-off valve showing signs of corrosion and verdigris buildup on brass components, confirmed proper operation after addressing packing nut issues. All fixtures tested and verified leak-free upon completion.
Performed comprehensive second opinion inspection on furnace and air conditioning system. Upon arrival, customer reported blower motor overdrawing amperage, suspected due to pet hair accumulation, and AC unit requiring multiple manual start attempts before maintaining operation. Conducted thorough system evaluation of both heating and cooling equipment. Inspection revealed extensive contamination of furnace blower wheel and secondary heat exchanger with accumulated debris, significantly restricting airflow and causing excessive system strain. Both blower motor and inducer motor exhibited oil leakage, indicating bearing failure from prolonged operation under stress conditions. Heat exchanger inspection identified critical concerns including severe temperature stress points, advanced rust formation, and corrosion throughout multiple sections. Visual assessment confirmed areas approaching failure threshold with potential breach points developing. Documented conditions with photographic
Completed preventative maintenance tune-up on both a mini split system and a standard air conditioning unit with no known issues reported. Performed comprehensive cleaning and inspection of all components on both systems, verifying proper operation and confirming both units are in good working condition. The mini split system, being only a few months old, showed excellent performance with no adjustments required.
Responded to a water heater leak in a residential basement utility area. Upon inspection, confirmed active leaking from a 12-year-old tanked water heater that had reached the end of its serviceable life. Removed and disposed of the old unit, then installed a new tanked water heater with proper venting and plumbing connections, including copper supply lines and exhaust piping. Tested the new installation for proper operation and verified no leaks at all connection points.
Completed scheduled air conditioning tune-up and maintenance inspection under family rewards agreement. Performed comprehensive system evaluation including inspection of control board, electrical connections, and all associated components. All equipment operating within normal parameters with no issues identified or repairs required at time of service.
Responded to no-cooling complaint on 1-year-old Lennox air conditioning system. Upon arrival, determined unit had been operated during cold weather conditions, causing system lockout. Performed system reset and verified proper startup sequence. Unit cycled on successfully and operated normally. Completed AC tune-up maintenance including inspection of outdoor condenser unit, electrical connections, and refrigerant lines. All components functioning as designed at time of departure.
Responded to service call for furnace that would not run. Replaced three pressure switches under parts and labor warranty. After installation, tested system with three successful startups to verify proper operation. Unit now functioning normally with all safety controls operating as designed.
Responded to emergency water leak with water actively penetrating ceiling from bathroom above. Upon arrival, main water supply had been shut off to prevent further damage. Conducted thorough inspection of bathroom area, including ceiling cavity, ventilation systems, and shower enclosure to identify leak source. Documentation photos captured ceiling damage, wallpaper water staining, textured ceiling deterioration, and shower door assembly configuration. Assessment determined extensive sheetrock removal would be required to access plumbing lines and complete repairs. Coordinated with restoration company for water damage mitigation and structural drying before plumbing repairs can proceed.
Responded to no heat call on commercial furnace system. Upon arrival, found unit operating on inducer motor only with no ignition sequence initiating. Performed diagnostic testing to verify inducer motor was providing adequate vacuum for pressure switch operation. Confirmed pressure switch opening and closing properly based on inducer status. Tested igniter with ohmmeter, readings within acceptable range. Traced electrical circuit through ignition sequence and determined control board was not sending voltage to igniter despite pressure switches being closed and all safety circuits satisfied. Diagnosed failed control board as root cause of no heat condition. Recommended replacement of both control board and inducer motor as preventive measure. Provided two temporary space heaters to maintain comfort until repairs could be completed. Documented findings with photos showing air filtration system and Daikin One thermostat displaying active heating call at 55°F setpoint with 57°F current te
# Shower Leak Repair - Master Bathroom Responded to a leaking shower in the master bathroom. Upon inspection, identified a loose pipe connection at the shower handle as the source of the leak. Removed the compromised pipe fitting, cleaned the threads, and properly re-sealed the connection using fresh Teflon tape and pipe dope. Reinstalled and securely tightened the pipe to the shower valve assembly, restoring proper seal and eliminating the leak. Documented existing water damage to ceiling access panel showing rust staining and mineral deposits from previous moisture intrusion.
Completed annual furnace tune-up and preventive maintenance inspection on residential heating system. Performed comprehensive system diagnostics using digital testing equipment, inspected all internal components including blower motor assembly, heat exchanger, control board, and electrical connections. Heat exchanger examination revealed visible wear and early signs of deterioration with rust staining on flue pipe assembly, indicating unit is approaching end of service life. All electrical connections, wiring harnesses, and control circuits tested and found operational. Documented current system condition with photographic evidence showing component wear patterns. Advised customer that due to age of equipment and progressive heat exchanger deterioration, replacement should be considered in near future to avoid potential safety concerns and system failure during heating season.
Completed warranty service by extending exhaust pipe 6" past intake to meet inspection requirements and installed locking caps on the system. Documented installation with photographic evidence of proper pipe spacing and configuration.
Responded to alert code 125 on recently installed thermostat reporting a control hardware error. Performed comprehensive inspection of all modules including bus, communication board, terminals and connections. Determined issue was caused by a momentary power/connection glitch that temporarily disrupted thermostat communication with system control module. Resolved by performing power reset procedure with successful system recovery.
Conducted a water heater evaluation for customer experiencing leakage from their 40-gallon tank water heater. Upon inspection, determined the unit was beyond repair due to significant leaking. Provided comprehensive replacement options including both standard tank and tankless water heater alternatives. Documented existing installation environment, including current plumbing connections and utility room configuration, to ensure accurate estimation for replacement work.
Responded to leak under kitchen sink following a recent garbage disposal installation. Diagnosed and replaced two faulty shut-off valves that were leaking, along with a leaking drain stem. Installed two new stops with water hammer arrestor for dishwasher and a new flanged tailpiece to resolve all leak sources.